NTP- D56 Create a Unidirectional Low-Order VC3 Circuit with Multiple Drops

When all the circuits are created, the main Circuits window appears. Verify that the circuits you created
Step 21
are correct.
Step 22
Complete the
a test circuit.
Stop. You have completed this procedure.
NTP-D56 Create a Unidirectional Low-Order VC3 Circuit with
Multiple Drops
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
where you will create the circuit. If you are already logged in, continue with
On the shelf graphic, verify that XC-VXL-10G or XC-VXL-2.5G cross-connect cards are installed in
Step 2
Slots 8 and 10.
Step 3
If you want to assign a name to the circuit source and destination ports before you create the circuit,
complete the
automatically based on circuit type, node name, and sequence number, continue with
From the View menu, choose Go to Network View.
Step 4
Click the Circuits tab, then click Create.
Step 5
In the Circuit Creation dialog box, complete the following fields:
Step 6
Click Next.
Step 7
Define the circuit attributes
Step 8
Cisco ONS 15454 SDH Procedure Guide, R7.0
6-38
"NTP-D135 Test Low-Order Circuits" procedure on page
This procedure creates a unidirectional low-order VC3 circuit with
multiple drops (destinations).
XC-VXL-10G or XC-VXL-2.5G cards must be installed at the circuit
source and destination nodes.
NTP-D127 Verify Network Turn-Up, page 6-5
As needed
Onsite or remote
Provisioning or higher
"DLP-D60 Log into CTC" task on page 17-49
"DLP-D314 Assign a Name to a Port" task on page
Circuit Type—Choose VC_LO_PATH_CIRCUIT.
Number of Circuits—Leave the default unchanged (1).
Auto-ranged—Unavailable when the Number of Circuits field is 1.
(Figure 6-6 on page
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters,
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Size—Choose VC3.
Bidirectional—Uncheck for this circuit.
Number of Circuits—Leave the default unchanged (1).
Chapter 6
Create Circuits and Low-Order Tunnels
6-53. Skip this step if you built
at an ONS 15454 SDH on the network
20-7. If you want CTC to assign a name
6-40):
Step
2.
Step
4.