DLP- D235 Roll One Cross-Connect from an Optical Circuit to a Second Optical Circuit
From the Circuit Roll Type drop-down list, choose Single to indicate that you want to roll a single
b.
connection from the Roll From circuit to the Roll To circuit.
c.
In the Roll From Circuit area, click the circuit that contains the Roll From connection.
Figure 19-9
Click Next.
Step 6
In the Pivot/Fixed Point 1 window, click the square representing the facility that you want to keep
Step 7
(Figure 19-6 on page
This facility is the fixed location in the cross-connect involved in the roll process. The identifier appears
in the text box below the graphic image. The facility that is not selected is the Roll From path. The
Roll From path is deleted after the roll is completed.
Click Next.
Step 8
In the Select New End Point area, choose the Slot, Port, and VC4 from the drop-down lists to identify
Step 9
the Roll To facility on the connection being rolled.
Click Finish.
Step 10
The statuses of the Roll From and Roll To circuits change from DISCOVERED to ROLL_PENDING in
the Circuits tab.
Click the Rolls tab. For the pending roll, view the Roll Valid Signal status. When one of the following
Step 11
conditions is met, continue with
If the Roll Valid Signal status is true, a valid signal was found on the new port.
If the Roll Valid Signal status is false, a valid signal was not found. Wait until the signal is found
before continuing with the next step. If the signal is not found, refer to the Circuits and Timing
section of the Cisco ONS 15454 SDH Troubleshooting Guide. To cancel the roll, see the
Cancel a Roll" task on page
The roll is a one-way destination roll and the Roll Valid Signal is false. It is not possible to get a
"true" Roll Valid Signal status for a one-way destination roll.
Note
Cisco ONS 15454 SDH Procedure Guide, R7.0
19-34
Selecting Roll Attributes for a Single Roll onto a Second Circuit
19-31).
Step
12.
19-43.
You cannot cancel an automatic roll after a valid signal is found.
Chapter 19
HOP
HOP
DLPs D200 to D299
"DLP-D240
78-17194-01