Dlp- D136 Provision Ce-100T-8 Ethernet Ports - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

DLP- D136 Provision CE-100T-8 Ethernet Ports

If you need to remove the SFP, see the
Step 6
page
Return to your originating procedure (NTP).
Step 7
DLP-D136 Provision CE-100T-8 Ethernet Ports
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
You can provision SONET contiguous concatenated (CCAT) or VCAT circuits for the CE-100T-8 before
Note
or after provisioning the card's Ethernet ports and/or packet-over-SDH (POS) ports. See the
Create an Automatically Routed High-Order Circuit" procedure on page 6-55
an Automatically Routed VCAT Circuit" procedure on page
Step 1
In node view, double-click the CE-100T-8 card graphic to open the card.
Step 2
Click the Provisioning > Ether Ports tabs.
For each CE-100T-8 port, provision the following parameters:
Step 3
Note
Cisco ONS 15454 SDH Procedure Guide, R7.0
18-30
If the SFP (PPM) is physically present when you delete the PPM provisioning, CTC transitions to
the deleted state; the ports (if any) are deleted, and the PPM is represented as a gray graphic in CTC.
The SFP can be provisioned again in CTC or the equipment can be removed, in which case the
removal causes the graphic to disappear.
20-32.
This task provisions CE-100T-8 Ethernet ports to carry traffic.
None
DLP-D60 Log into CTC, page 17-49
As needed
Onsite or remote
Provisioning or higher
Port Name—If you want to label the port, enter the port name.
Circuit table displays port name of the POS port and not the Ethernet port.
Admin State—Choose Unlocked to put the port in service.
Expected Speed—Choose the expected speed of the device that is or will be attached to the Ethernet
port. If you know the speed, choose 100 Mbps or 10 Mbps to match the attached device. If you do
not know the speed, choosing Auto enables autonegotiation for the speed of the port, and the
CE-100T-8 port will attempt to negotiate a mutually acceptable speed with the attached device.
Expected Duplex—Choose the expected duplex of the device that is or will be attached to the
Ethernet port. If you know the duplex, choose Full or Half to match the attached device. If you do
not know the duplex, choosing Auto enables autonegotiation for the duplex of the port, and the
CE-100T-8 port will attempt to negotiate a mutually acceptable duplex with the attached device.
Enable Flow Control—Click this check box to enable flow control on the port (default). If you do
not want to enable flow control, uncheck the box. The CE-100T-8 attempts to negotiate symmetrical
flow control with the attached device.
"DLP-D336 Remove GBIC or SFP/XFP Device" task on
6-97, as needed.
Chapter 18
DLPs D100 to D199
"NTP-D323
or the
"NTP-D283 Create
78-17194-01