Cisco ONS 15454 SDH Procedure Manual page 771

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 21
DLPs D400 to D499
To view node alarm history:
Step 2
Click the History > Session tabs to view the alarms and conditions (events) raised during the current
a.
session.
Click the History > Shelf tabs to view the alarm and condition history for the node.
b.
If you check the Alarms check box, the node's alarm history appears. If you check the Events check
box, the node's Not Alarmed and transient event history appears. If you check both check boxes,
you will retrieve node history for alarms and events.
Click Retrieve to view all available messages for the History > Shelf tab.
c.
Tip
To view network alarm history from node view:
Step 3
From the View menu, choose Go to Network View.
a.
Click the History tab.
b.
Alarms and conditions (events) raised during the current session appear.
To view card alarm history from node view:
Step 4
From the View menu, choose Go to Previous View.
a.
Double-click a card on the shelf graphic to open the card-level view.
b.
Note
Click the History > Session tabs to view the alarm messages raised during the current session.
c.
Click the History > Card tabs and click Retrieve to retrieve all available alarm messages for the
d.
card.
If you check the Alarms check box, the node's alarm history appears. If you check the Events check
box, the node's Not Alarmed and transient event history appears. If you check both check boxes, you
will retrieve node history for alarms and events.
Note
Raised and cleared alarm messages (and events, if selected) appear.
Return to your originating procedure (NTP).
Step 5
78-17194-01
Double-click an alarm in the alarm table or an event (condition) message in the history table to
display the view that corresponds to the alarm message. For example, double-clicking a card
alarm takes you to card view. In network view, double-clicking a node alarm takes you to node
view.
TCC2/TCC2P cards and cross-connect cards do not have a card view.
The ONS 15454 SDH can store up to 640 critical alarm messages, 640 major alarm
messages, 640 minor alarm messages, and 640 condition messages. When any of these limits
is reached, the ONS 15454 SDH discards the oldest events in that category.
DLP- D424 View Alarm or Event History
Cisco ONS 15454 SDH Procedure Guide, R7.0
21-5