To set the filter for ring, node, link, and source and drop type, click the Advanced tab and complete the
Step 4
following. If you do not want to make advanced filter selections, continue with
If you made selections on the General tab, click Yes in the confirmation box to apply the settings.
a.
In the Advanced tab of the Circuit Filter dialog box, set the following filter attributes as necessary:
b.
Cisco ONS 15454 SDH Procedure Guide, R7.0
19-66
Direction—Choose one to filter circuits based on direction: Any (direction not used to filter
circuits), 1-way (display only one-way circuits), or 2-way (display only two-way circuits).
OCHNC Dir—(DWDM optical channel network connections [OCHNCs] only) Refer to the
Cisco ONS 15454 DWDM Procedure Guide for dense wavelength division multiplexing
(DWDM) information.
OCHNC Wlen—(DWDM OCHNCs only) Refer to the Cisco ONS 15454 DWDM Procedure
Guide for DWDM information.
Status—Choose a circuit status to filter the circuits. For more information about circuit statuses,
see
Table 20-32 on page
State—Choose one to filter circuits based on state: Locked (display only out-of-service
circuits), Unlocked (display only in-service circuits; OCHNCs have Unlocked status only), or
Locked-partial (display only circuits with cross-connects in mixed service states).
Protection—Choose a protection type to filter the circuits. For more information about
protection types, see
Table 20-31 on page
Slot—Enter a slot number to filter circuits based on the source or destination slot; otherwise
leave the field blank.
Port—Enter a port number to filter circuits based on the source or destination port; otherwise
leave the field blank.
Type—Choose one to filter circuits based on type: Any (type not used to filter circuits),
VC_HO_PATH_CIRCUIT (displays VC4 and VC4-Nc circuits), VC_LO_PATH_CIRCUIT
(displays only VC3, VC11, and VC12 circuits), VC_LO_PATH_TUNNEL (displays only
low-order tunnels), VC_LO_PATH_AGGREGATION (displays only low-order aggregation
points), VC_HO_PATH_VCAT_CIRCUIT (displays high-order VCAT circuits),
VC_LO_PATH_VCAT_CIRCUIT (displays low-order VCAT circuits), or OCHNC (displays
only OCHNCs; refer to the Cisco ONS 15454 DWDM Procedure Guide for DWDM
information).
Size—Click the appropriate check boxes to filter circuits based on size: VC11, VC12, VC3,
VC4, VC4-2c, VC4-3c, VC4-4c, VC4-6c, VC4-8c, VC4-9c, VC4-16c, VC4-64c,
10 Gbps FEC, Equipped non specific, Multi-rate, 2.5 Gbps No FEC, 10 Gbps No FEC, and
2.5 Gbps FEC. The check boxes shown depend on what you chose in the Type field.
If you chose Any, all sizes are available. If you chose LO_PATH_CIRCUIT, only VC3, VC11,
and VC12 sizes are available. If you chose LO_PATH_TUNNEL or
LO_PATH_AGGREGATION, only VC4 is available. If you chose
VC_HO_PATH_VCAT_CIRCUIT, only VC4 and VC4-4c are available. If you chose
VC_LO_PATH_VCAT_CIRCUIT, only VC3 is available.
Ring—Choose the ring from the drop-down list.
Node—Click the check boxes by each node in the network to filter circuits based on node.
Link—Choose the desired link in the network.
Source/Drop—Choose one of the following to filter circuits based on whether they have one or
multiple sources and drops: One Source and One Drop Only or Multiple Sources or Multiple
Drops.
20-78.
20-77.
Chapter 19
DLPs D200 to D299
Step
5.
78-17194-01