Table 20-26 Stm-N Threshold Options - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 20
DLPs D300 to D399
Table 20-26
Parameter
NPJC-PDET
PPJC-PGEN
NPJC-PGEN
PSC
PSD
PSC-W
PSD-W
PSC-S
PSD-S
PSC-R
PSD-R
15 Min radio button
1 Day radio button
78-17194-01
STM-N Threshold Options (continued)
Description
Negative Pointer Justification Count, STS Path Detected. Available for
Line; Near End and Far End.
Positive Pointer Justification Count, STS Path Generated. Available for
Line; Near End and Far End.
Negative Pointer Justification Count, STS Path Generated. Available for
Line; Near End and Far End.
Protection Switching Count (Line). Available for Line; Near End and Far
End.
Protection Switch Duration (Line). Available for Line; Near End and Far
End.
Protection Switching Count—Working Line. Available for Line; Near End
and Far End.
MS-SPRing is not supported on the STM-1 card; therefore, the
Note
PSC-W performance monitoring (PM) parameter does not
increment.
Protection Switching Duration—Working Line. Available for Line; Near
End and Far End.
MS-SPRing is not supported on the STM-1 card; therefore, the
Note
PSD-WPM parameter does not increment.
Protection Switching Count—Span. Available for Line; Near End and Far
End.
MS-SPRing is not supported on the STM-1 card; therefore, the
Note
PSC-S PM parameter does not increment.
Protection Switching Duration—Span. Available for Line; Near End and
Far End.
MS-SPRing is not supported on the STM-1 card; therefore, the
Note
PSD-S PM parameter does not increment.
Protection Switching Count—Ring. Available for Line; Near End and Far
End.
MS-SPRing is not supported on the STM-1 card; therefore, the
Note
PSC-R PM parameter does not increment.
Protection Switching Duration—Ring. Available for Line; Near End and
Far End.
MS-SPRing is not supported on the STM-1 card; therefore, the
Note
PSD-R PM parameter does not increment.
Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 15-minute intervals.
Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 1-day intervals.
DLP- D343 Change SDH Threshold Settings for STM-N Cards
Cisco ONS 15454 SDH Procedure Guide, R7.0
20-55

Advertisement

Table of Contents
loading

Table of Contents