Dlp- D238 Roll Two Cross-Connects From One Optical Circuit To A Second Optical Circuit - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 19
DLPs D200 to D299
Note
Step 20
For both manual and automatic rolls, click Finish to complete the circuit roll process.
Return to your originating procedure (NTP).
Step 21
DLP-D238 Roll Two Cross-Connects from One Optical Circuit to a Second
Optical Circuit
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
From the View menu, choose Go To Network View.
Step 1
Click the Circuits tab.
Step 2
Step 3
Press Ctrl and click the two circuits that you want to use in the roll process.
The Roll From path will be on one circuit and the Roll To path will be on the other circuit. The circuits
must have a DISCOVERED status and must be the same size and direction for you to start a roll. The
planned Roll To circuit must not carry traffic. The first Roll To path must be DCC connected to the source
node of the Roll To circuit, and the second Roll To path must be DCC connected to the destination node
of the Roll To circuit.
From the Tools menu, choose Circuits > Roll Circuit.
Step 4
In the Roll Attributes area, complete the following:
Step 5
a.
b.
c.
Click Next.
Step 6
In the Pivot/Fixed Point 1 window, click the square representing the fixed path of the first cross-connect
Step 7
to be rolled
This path is a fixed point in the cross-connect involved in the roll process. The path identifier appears in
the text box below the graphic image. The path that is not selected contains the Roll From path. The
Roll From path is deleted after the roll is completed.
Click Next.
Step 8
78-17194-01
You cannot complete a roll if you cancelled the sibling roll. You must complete the two rolls
together.
This task reroutes a network path using two optical circuits by allowing
CTC to select the Roll To path on the second circuit automatically.
None
DLP-D60 Log into CTC, page 17-49
As needed
Onsite or remote
Provisioning and higher
From the Circuit Roll Mode drop-down list, choose Auto to create an automatic roll (required for a
1-way source roll) or Manual to create a manual roll (required for 1-way destination roll).
From the Circuit Roll Type drop-down list, choose Dual.
In the Roll From Circuit area, click the circuit that contains the Roll From path.
(Figure 19-6 on page

DLP- D238 Roll Two Cross-Connects from One Optical Circuit to a Second Optical Circuit

19-31).
Cisco ONS 15454 SDH Procedure Guide, R7.0
19-41

Advertisement

Table of Contents
loading

Table of Contents