Cisco ONS 15454 SDH Procedure Manual page 233

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 6
Create Circuits and Low-Order Tunnels
Review the circuit constraints. To change the circuit routing order, choose a node in the
h.
Required Nodes/Lines lists and click the Up or Down buttons to change the circuit routing order.
Click Remove to remove a node or span.
If you selected Review Route Before Creation in
Step 19
continue with
Click Next.
a.
Review the circuit route. To add or delete a circuit span, choose a node on the circuit route. Blue
b.
arrows show the circuit route. Green arrows indicate spans that you can add. Click a span arrowhead,
then click Include to include the span or Remove to remove the span.
If the provisioned circuit does not reflect the routing and configuration you want, click Back to
c.
verify and change circuit information. If the circuit needs to be routed to a different path, see the
"NTP-D324 Create a Manually Routed High-Order Circuit" procedure on page 6-60
circuit route yourself.
Step 20
If you selected Review Route Before Creation in
the route in the Route Review/Edit window. As necessary, click Add MS-SPRing DRI to add another
DRI. Click Remove to remove a DRI assignment. Click the Included Spans tab to view the spans. The
map graphic updates as you apply changes.
Click Finish. One of the following occurs, based on the circuit properties that you provisioned in the
Step 21
Circuit Creation dialog box:
If you entered more than 1 in the Number of Circuits field and selected Auto-ranged, CTC
automatically creates the number of circuits entered in Number of Circuits. If auto-ranging cannot
complete all the circuits, for example, because sequential ports are unavailable on the source or
destination, a dialog box appears. Set the new source or destination for the remaining circuits, then
click Finish to continue auto-ranging. After completing the circuits, the Circuits window appears.
If you entered more than 1 in Number of Circuits and did not choose Auto-ranged, the Circuit
Creation dialog box appears so you can create the remaining circuits. Repeat Steps
each additional circuit. After completing the circuits, the Circuits window appears.
In the Circuits window, verify that the circuits you created appear in the circuits list.
Step 22
Complete the following as necessary. Skip this step if you built a test circuit.
Step 23
Complete the
a.
Complete the
b.
Stop. You have completed this procedure.
78-17194-01
Step
21:
"NTP-D62 Test High-Order Circuits" procedure on page
"NTP-D149 Test G-Series Circuits" procedure on page
NTP- D323 Create an Automatically Routed High-Order Circuit
Step
13, complete the following substeps; otherwise,
Step
13, click Next. If not, continue with
6-95.
Cisco ONS 15454 SDH Procedure Guide, R7.0
to assign the
Step
21. View
7
through
20
for
6-66.
6-59

Advertisement

Table of Contents
loading