Dlp- D53 Set Up A Solaris Workstation For A Craft Connection To An Ons 15454 Sdh - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 17
DLPs D1 to D99
DLP-D53 Set Up a Solaris Workstation for a Craft Connection to an
ONS 15454 SDH
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Log into the workstation as the root user.
Step 1
Check to see if the interface is plumbed by typing:
Step 2
# ifconfig device
For example:
# ifconfig hme1
If the interface is plumbed, a message similar to the following appears:
hme1:flags=1000842<BROADCAST,RUNNING,MULTICAST,IPv4>mtu 1500 index 2 inet 0.0.0.0 netmask
0
If a message similar to this one appears, go to
If the interface is not plumbed, a message similar to the following appears:
ifconfig: status: SIOCGLIFFLAGS: hme1: no such interface.
If a message similar to this one appears, go to
Plumb the interface by typing:
Step 3
# ifconfig device plumb
For example:
# ifconfig hme1 plumb
Step 4
Configure the IP address on the interface by typing:
# ifconfig interface ip-address netmask netmask up
For example:
# ifconfig hme0 192.1.0.3 netmask 255.255.255.0 up
Note
Step 5
In the Subnet Mask field, type 255.255.255.0. Skip this step if you checked Craft Access Only on the
Provisioning > Network > General > Gateway Settings tab.
78-17194-01
This task sets up a Solaris workstation for a craft connection to the
ONS 15454 SDH.
None
NTP-D278 Set Up Computer for CTC, page 3-2
As needed
Onsite
None
Enter an IP address that is identical to the ONS 15454 SDH IP address except for the last octet.
The last octet must be 1 or 3 through 254.

DLP- D53 Set Up a Solaris Workstation for a Craft Connection to an ONS 15454 SDH

Step
4.
Step
3.
Cisco ONS 15454 SDH Procedure Guide, R7.0