DLP- D52 Set Up a Windows PC for Craft Connection to an ONS 15454 SDH Using Automatic Host Detection

DLP-D52 Set Up a Windows PC for Craft Connection to an ONS 15454 SDH Using
Automatic Host Detection
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Verify the operating system that is installed on your computer:
Step 1
a.
b.
c.
According to the Windows operating system installed on your computer, perform one of the following
Step 2
steps:
If you have Windows 98 installed on your PC, complete the following steps to change its TCP/IP
Step 3
configuration:
a.
b.
c.
d.
e.
f.
g.
Cisco ONS 15454 SDH Procedure Guide, R7.0
17-42
This task sets up your computer for local craft connection to the
ONS 15454 SDH when:
NIC
NTP-D278 Set Up Computer for CTC, page 3-2
As needed
Onsite
None
From the Windows Start menu, choose Settings > Control Panel.
In Windows XP, you can choose Control Panel directly from the Start menu. Make sure you
Note
are in Classic View before continuing with this procedure.
In the Control Panel window, double-click the System icon.
On the General tab of the System Settings window, verify that the Windows operating system is one
of the following: Windows 98, Windows NT 4.0, Windows 2000, or Windows XP.
For Windows 98, complete
For Windows NT 4.0, complete
For Windows 2000, complete
For Windows XP, complete
From the Windows Start menu, choose Settings > Control Panel.
In the Control Panel dialog box, click the Network icon.
In the Network dialog box select TCP/IP for your NIC, then click Properties.
In the TCP/IP Properties dialog box, click the DNS Configuration tab and choose Disable DNS.
Click the WINS Configuration tab and choose Disable WINS Resolution.
Click the IP Address tab.
In the IP Address window, click Specify an IP address.
You will connect to the ONS 15454 SDH Ethernet port or the RJ-45
jack on the MIC-C/T/P FMEC either directly or through a hub.
You will connect to multiple ONS 15454 SDHs and do not want to
reconfigure your IP address each time.
You do not need to access non-ONS 15454 SDH applications such as
ping and tracert (trace route).
Step