Chapter 17
DLPs D1 to D99
Figure 17-1
Using the hex tool that shipped with the assembly, install the two set screws into the holes that will not
Step 3
be used to mount the shelf. Let the set screws protrude sufficiently to hold the mounting brackets.
Lift the shelf assembly to the desired position in the rack.
Step 4
Align the screw holes on the mounting brackets with the mounting holes in the rack.
Step 5
Using the Phillips screwdriver, install one mounting screw in each side of the assembly.
Step 6
When the shelf assembly is secured to the rack, install the remaining mounting screws.
Step 7
Note
Step 8
Using the hex tool, remove the temporary set screws.
Step 9
Return to your originating procedure (NTP).
78-17194-01
Mounting an ONS 15454 SDH in a Rack
F A N
F A IL
C R
IT
M A
J
M IN
Use at least one set of the horizontal screw slots on the ONS 15454 SDH to prevent slippage.
DLP- D5 Mount the Shelf Assembly in a Rack (One Person)
Equipment rack
Cisco ONS 15454 SDH Procedure Guide, R7.0
17-5