Dlp- D225 Enable Alarm Filtering - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

DLP- D225 Enable Alarm Filtering

Type 512 in the Variable Value field.
Step 7
Click OK.
Step 8
Reboot your PC.
Step 9
Return to your originating procedure (NTP).
Step 10
DLP-D225 Enable Alarm Filtering
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
At node, network, or card view, click the Alarms tab.
Step 1
Click the Filter tool at the lower-right side of the bottom toolbar.
Step 2
Alarm filtering is enabled if the tool is selected and disabled if the tool is raised (not selected).
Alarm filtering will be enabled in the card, node, and network views of the Alarms tab at the current node
and for all other nodes in the network. If, for example, the Alarm Filter tool is enabled in the Alarms tab
of node view at one node, the Alarms tab in the network and card views of that node will also show the
tool enabled. All other nodes in the network will also have the tool enabled.
If you filter an alarm in card view, the alarm will still be displayed in node view. In this view, the card
will display the color of the highest-level alarm. The alarm is also shown for the node in network view.
If you want alarm filtering enabled when you view conditions, repeat Steps
Step 3
window.
If you want alarm filtering enabled when you view alarm history, repeat Steps
Step 4
window.
Step 5
Return to your originating procedure (NTP).
Cisco ONS 15454 SDH Procedure Guide, R7.0
19-24
This task enables alarm filtering for alarms, conditions, or event history in
all network nodes.
None
DLP-D60 Log into CTC, page 17-49
As needed
Onsite or remote
Retrieve or higher
Chapter 19
DLPs D200 to D299
1
and
2
using the Conditions
1
and
2
using the History
78-17194-01