Dlp- D28 Create A Four-Fiber Ms-Spring Manually - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

DLP- D28 Create a Four-Fiber MS-SPRing Manually

Click the Circuits tab.
Step 5
Choose the circuits that you want to delete, then click Delete.
Step 6
In the Delete Circuits confirmation dialog box, check one or both of the following, as needed:
Step 7
Step 8
Complete one of the following:
Step 9
If you want to save the information in the CTC Alerts dialog box, complete the following steps. If you
do not want to save the information, continue with the next step.
a.
b.
c.
Step 10
Click Close to close the CTC Alerts dialog box.
Complete the
Step 11
Return to your originating procedure (NTP).
Step 12
DLP-D28 Create a Four-Fiber MS-SPRing Manually
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, click the Provisioning > Ring tabs.
Step 1
Cisco ONS 15454 SDH Procedure Guide, R7.0
17-22
Set drop ports to Locked,disabled—Puts the circuit source and destination ports out of service if the
circuit is the same size as the port or is the only circuit using the port. If the circuit is not the same
size as the port or the only circuit using the port, CTC does not change the port service state.
Notify when completed—If checked, the CTC Alerts dialog box will indicate when all circuit
source/destination ports are Locked,disabled and the circuit is deleted. During this time, you cannot
perform other CTC functions. If you are deleting many circuits, waiting for confirmation might take
a few minutes. Circuits are deleted whether or not this check box is checked.
The CTC Alerts dialog box will not automatically open to show a deletion error unless you
Note
checked All alerts or Error alerts only in the CTC Alerts check box. For more information,
see the
"DLP-D25 Configure the CTC Alerts Dialog Box for Automatic Popup" task on
page
17-20. If the CTC Alerts dialog box is not set to open automatically with a notification,
the red triangle inside the CTC Alerts toolbar icon indicates that a notification exists.
If you checked Notify when completed, the CTC Alerts dialog box appears. If you want to save the
information, continue with
If you did not check Notify when completed, the Circuits window appears. Continue with
Click Save.
Click Browse and navigate to the directory where you want to save the file.
Type the file name using a .txt file extension, and click OK.
"NTP-D108 Back Up the Database" procedure on page
This task creates a four-fiber MS-SPRing at each MS-SPRing-provisioned
node without using the MS-SPRing wizard.
None
DLP-D60 Log into CTC, page 17-49
Required
Onsite or remote
Provisioning or higher
Step
9. If you do not want to save the information, continue with
Chapter 17
DLPs D1 to D99
Step
Step
15-5.
78-17194-01
10.
11.

Advertisement

Table of Contents
loading

Table of Contents