Ntp- D345 Edit Network Element Defaults - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 15
Maintain the Node
To verify that the tray has plugged into the backplane, check that the LCD on the front of the fan tray is
Step 10
activated.
Step 11
Replace the door and reattach the ground strap.
Stop. You have completed this procedure.
NTP-D345 Edit Network Element Defaults
Purpose
Tools/Equipment
Prerequisite Procedures None
Required/As Needed
Onsite/Remote
Security Level
For a list of card and node default settings, refer to the "Network Element Defaults" appendix in the
Note
Cisco ONS 15454 SDH Reference Manual. To change card settings individually (that is, without
changing the defaults), see
Chapter 11, "Change Node Settings."
Complete the
Step 1
defaults.
Click the Provisioning > Defaults tabs.
Step 2
Under Defaults Selector, choose a card type (if editing card-level defaults), CTC (if editing CTC
Step 3
defaults), or NODE (if editing node-level defaults). Click the node name (at the top of the Defaults
Selector column) to display all available NE defaults in the Default Name column. To selectively display
just the defaults for a given card type, for node-level, or for CTC-level, you can drill down the Defaults
Selector menu structure.
Locate a default that you want to change in the Default Name column.
Step 4
Click the Default Value column for the default property you are changing and either choose a value from
Step 5
the drop-down list (when available), or type the desired new value.
Note
Click Apply. (If it is unavailable, click in the Default Name column to activate the button.) You can
Step 6
modify multiple default values before applying the changes.
A pencil icon will appear next to any default value that will be changed as a result of editing the defaults
file.
78-17194-01
This procedure edits factory-configured NE defaults using the NE Defaults
editor. The new defaults can either be applied only to the node on which
they are edited or exported to a file and imported for use on other nodes.
None
As needed
Onsite or remote
Superuser
Chapter 10, "Change Card Settings."
"DLP-D60 Log into CTC" task on page 17-49
If you click Reset before you click Apply, all values will return to their original settings.

NTP- D345 Edit Network Element Defaults

To change node settings, see
CTC at the node where you want to edit NE
Cisco ONS 15454 SDH Procedure Guide, R7.0