Ntp- D261 Set Up A Computer For A Corporate Lan Connection To The Ons 15454 Sdh - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 3
Connect the PC and Log into the GUI
NTP-D261 Set Up a Computer for a Corporate LAN Connection to
the ONS 15454 SDH
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
If your computer is already connected to the corporate LAN, go to
Step 1
network settings for craft access to the ONS 15454 SDH, change the settings back to the corporate LAN
access settings. This generally means:
Connect a straight-through (CAT-5) LAN from the PC or Solaris workstation NIC card to a corporate
Step 2
LAN port.
If your computer is connected to a proxy server, disable proxy service or add the ONS 15454 SDH nodes
Step 3
as exceptions. To disable proxy service, complete one of the following tasks, depending on the web
browser you use:
Continue with the
Step 4
Stop. You have completed this procedure.
78-17194-01
This procedure sets up your computer to access the ONS 15454 SDH
through a corporate LAN.
NIC, also referred to as an Ethernet card
Straight-through (CAT 5) LAN cable
As needed
Onsite or remote
None
Set the IP Address on the TCP/IP dialog box back to Obtain an IP address automatically
(Windows 98) or Obtain an IP address from a DHCP server (Windows NT, 2000, or XP).
If your LAN requires that Domain Name System (DNS) or Windows Internet Naming Service
(WINS) be enabled, change the setting on the DNS Configuration or WINS Configuration tab of the
TCP/IP dialog box.
DLP-D56 Disable Proxy Service Using Internet Explorer (Windows), page 17-47
DLP-D57 Disable Proxy Service Using Netscape (Windows and UNIX), page 17-48
"NTP-D23 Log into the ONS 15454 SDH GUI" procedure on page

NTP- D261 Set Up a Computer for a Corporate LAN Connection to the ONS 15454 SDH

NTP-D278 Set Up Computer for CTC, page 3-2
The ONS 15454 SDH must be provisioned for LAN connectivity,
including IP address, subnet mask, and default gateway.
The ONS 15454 SDH must be physically connected to the corporate
LAN.
The CTC computer must be connected to the corporate LAN that has
connectivity to the ONS 15454 SDH.
Cisco ONS 15454 SDH Procedure Guide, R7.0
Step
3. If you changed your computer
3-7.
3-5