Ntp- D83 Create A Unidirectional Low-Order Vc12 Circuit With Multiple Drops - Cisco ONS 15454 SDH Procedure Manual

Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 6
Create Circuits and Low-Order Tunnels
Click Next. In the Route Review/Edit area, node icons appear for circuit routing. The circuit source node
Step 17
is selected. Green arrows pointing from the source node to other network nodes indicate spans that are
available for routing the circuit.
Complete the
Step 18
circuit you are creating.
Click Finish. CTC compares your manually provisioned circuit route with the specified path diversity
Step 19
option you chose in
displays an error message and allows you to change the circuit path.
If you entered more than 1 in the Number of Circuits field, the Circuit Creation dialog box appears so
Step 20
you can create the remaining circuits. Repeat Steps
When all the circuits are created, the main Circuits window appears. Verify that the circuits you created
Step 21
are correct.
Complete the
Step 22
a test circuit.
Stop. You have completed this procedure.
NTP-D83 Create a Unidirectional Low-Order VC12 Circuit with
Multiple Drops
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
where you will create the circuit. If you are already logged in, continue with
Complete the following:
Step 2
a.
b.
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 3
complete the
automatically based on circuit type, node name, and sequence number, continue with
Step 4
From the View menu, choose Go to Network View.
Step 5
Click the Circuits tab, then click Create.
Step 6
In the Circuit Creation dialog box, complete the following fields:
78-17194-01
"DLP-D3 Provision a Low-Order VC12 Circuit Route" task on page 17-2
Step
14. If the path does not meet the specified path diversity requirement, CTC
"NTP-D135 Test Low-Order Circuits" procedure on page
This procedure creates a unidirectional low-order VC12 circuit with
multiple drops (destinations).
XC-VXC-10G, XC-VXL-10G, or XC-VXL-2.5G cards must be installed
at the circuit source and destination nodes.
NTP-D127 Verify Network Turn-Up, page 6-5
As needed
Onsite or remote
Provisioning or higher
"DLP-D60 Log into CTC" task on page 17-49
On the shelf graphic, verify that XC-VXC-10G, XC-VXL-10G, or XC-VXL-2.5G cross-connect
cards are installed in Slots 8 and 10.
Click the Provisioning > Cross-Connect tabs and set the Low Order Payload Type to VC-12 or
VC-11 and VC-12 (Mixed Mode).
"DLP-D314 Assign a Name to a Port" task on page

NTP- D83 Create a Unidirectional Low-Order VC12 Circuit with Multiple Drops

6
through
19
at an ONS 15454 SDH on the network
20-7. If you want CTC to assign a name
Cisco ONS 15454 SDH Procedure Guide, R7.0
for the VC12
for each additional circuit.
6-53. Skip this step if you built
Step
2.
Step
4.
6-27