O3: Copy Function - YASKAWA GA800 Programming Manual

Ac drive for industrial applications
Table of Contents

Advertisement

2.11 o: Keypad-Related Settings
3 : Alarm Only
4 : No Alarm Display

o3: Copy Function

o3 parameters set the operation of the parameter backup function.
o3-01: Copy Keypad Function Selection
No.
Name
(Hex.)
o3-01
Copy Keypad Function
Selection
(0515)
0 : Copy Select
1 : Backup (drive → keypad)
The parameter setting values are read from the drive and saved in the keypad.
2 : Restore (keypad → drive)
Copies the parameter setting values saved in the keypad to a different drive.
3 : Verify (check for mismatch)
Makes sure that the parameter setting values in the drive agree with the parameters saved in the keypad.
4 : Erase (backup data of keypad)
Deletes the parameter setting values saved in the keypad.
o3-02: Copy Allowed Selection
No.
Name
(Hex.)
o3-02
Copy Allowed Selection
(0516)
Note:
When you select [Parameter Backup] on the keypad menu screen to do the backup function, the drive automatically sets o3-02 = 1.
0 : Disabled
1 : Enabled
o3-04: Select Backup/Restore Location
No.
Name
(Hex.)
o3-04
Select Backup/Restore
Location
(0B3E)
You can use the LCD keypad to make a maximum of 4 parameter backup sets.
0 : Memory Location 1
1 : Memory Location 2
2 : Memory Location 3
3 : Memory Location 4
o3-05: Select Items to Backup/Restore
No.
Name
(Hex.)
o3-05
Select Items to Backup/
Restore
(0BDA)
522
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that saves and copies drive parameters to a different drive with the keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection = Backup (drive →
keypad)].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the storage location for drive parameters when you back up and restore parameters. This
parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets which parameters are backed up, restored, and referenced. This parameter is only available when
using an LCD keypad.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
(Range)
0
(0 - 4)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0 - 3)
Default
(Range)
1
(0, 1)

Advertisement

Table of Contents
loading