6.12.1. Changing VOD, Pre-emphasis Using Direct Reconfiguration Flow

1. Perform the necessary steps from steps 1 to 7 in Steps to Perform Dynamic
Reconfiguration.
2. Read from the PMA analog feature address of the channel you want to change. For
example, to change pre-emphasis 1st post-tap, read and store the value of
address 0x105.
3. Select a valid value for the feature according to the Cyclone 10 GX register map.
For example, a valid setting for pre-emphasis 1st post-tap has a bit encoding of
5'b00001.
4. Perform a read-modify-write to the address of the PMA analog feature using the
valid value. For example, to change the pre-emphasis 1st post-tap, write 5'b00001
to address 0x105.
5. Perform the necessary steps from steps 9 to 12 in Steps to Perform Dynamic
Reconfiguration.
Table 185.
Register Map for PMA Analog Feature
PMA Analog Feature
Pre-emphasis 1st post-tap
Pre-emphasis 1st post-tap polarity
Pre-emphasis 2nd post-tap
Pre-emphasis 2nd post-tap polarity
Pre-emphasis 1st pre-tap
Pre-emphasis 1st pre-tap polarity
Pre-emphasis 2nd pre-tap
Pre-emphasis 2nd pre-tap polarity
Differential output voltage (V
The PMA analog settings are governed by a set of rules. Not all combinations of V
and pre-emphasis are valid. The following table lists the maximum pre-emphasis
settings for the corresponding V
Table 186.
Valid Maximum (Absolute) Pre-Emphasis Settings
V
OD
31
30
29
28
27
Send Feedback
)
OD
settings.
OD
Maximum (Absolute) Pre-Emphasis Settings
1st Post-Tap
1st Pre-Tap
25
25
25
25
25
Address
Bit
0x105
[4:0]
0x105
[6]
0x106
[3:0]
0x106
[5]
0x107
[4:0]
0x107
[5]
0x108
[2:0]
0x108
[4]
0x109
[4:0]
2nd Post-Tap
16
12
16
11
16
10
16
9
16
8
®
®
Intel
Cyclone
Values
5'b00000 - 5'b11001
1'b0 = positive
1'b1 = negative
4'b0000 - 4'b1100
1'b0 = positive
1'b1 = negative
5'b00000 - 5'b10000
1'b0 = positive
1'b1 = negative
3'b000 - 3'b111
1'b0 = positive
1'b1 = negative
5'b00000 - 5'b11111
OD
2nd Pre-Tap
7
6
5
4
3
continued...