Siemens SINAMICS G150 Manual page 1188

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

n_set before filter
[6030.1]
r0060
100 ms
n_act unsmoothed
[4715.6]
r0063[0]
100 ms
T_smth display
p0045
f_outp
<1> [6730.5]
<2> [6731.5]
r0066
100 ms
<3> [6732.5]
Vdc_act
<1> [6730.1]
<2> [6731.1]
r0070
100 ms
<3> [6732.1]
I_act abs. value unsmoothed
[6714.8]
r0068[0]
300 ms
T_smth display
p0045
cos phi actual val
<1> [6730.1]
r0087
<3> [6732.1]
3
U_output
<1> [6730.4]
<2> [6731.4]
r0072
100 ms
<3> [6732.4]
<1> For induction motors.
<2> For synchronous motors.
<3> Only for SINAMIC S120/S150 and separately-excited synchronous motors.
1
2
DO: VECTOR
Vector control - Display signals
n_set smooth
r0020
n_act smooth
r0021
n_act rpm smooth
r0022
n_act
Smoothed with p0045
r0063[1]
f_outp smooth
r0024
Vdc smooth
r0026
I_act abs value smooth
r0027
I_act abs. value
[7017.6]
smoothed with p0045
[8014.1]
r0068[1]
[8017.1]
[8018.1]
Power drawn
r0082[2]
U_outp smooth
r0025
3
4
Modulation depth
<1> [6730.5]
<2> [6731.5]
r0074
<3> [6732.5]
Id_act
[6714.8]
r0076
Iq_act
[6714.8]
r0078
<1> [6730.1]
<2> [6721.8]
<3> [6732.1]
M
Iq
n_act unsmoothed
[4715.7]
r0063[0]
M_act unsmoothed
[6799.8]
r0080[0]
P_act unsmoothed
[6799.8]
r0082[0]
Cos phi actual value
<1> [6730.1]
<2> [6731.1]
r0087
<3> [6732.1]
5
6
fp_6799_54_eng.vsd
11.06.13 V04.07.00
Modulation depth, smooth
100 ms
r0028
Id_act smooth
300 ms
r0029
Iq_act smooth
300 ms
r0030
M_act
r0080[0]
[6799.5]
T_smth display
p0045
M_act
r0080[1]
P_act unsmoothed
r0082[0]
[6799.5]
T_smth display
p0045
P_act Smoothed with p0045
r0082[1]
M_act smooth
100 ms
r0031
P_active_actual smooth
r0032
100 ms
cos phi smooth
300 ms
r0038
7
8
Function diagram
- 6799 -
S120/S150/G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents