Securing the robot to the base plate/foundation
Use this procedure to secure robot to base plate after fitting plate to the foundation.
1
2
3
4
5
6
Product manual - IRB 6790
3HAC063331-001 Revision: B
Action
Fit two guide pins to the guide pin holes in the
base plate.
Note
All screws and pins are delivered in a plastic
bag together with the base plate.
Lift the robot.
Move robot close to its installation location.
Guide the robot gently using two M24 screws
while lowering it into its mounting position.
Fit the bolts and washers in the base attachment
holes.
Tighten bolts in a crosswise pattern to ensure
that the base is not distorted.
© Copyright 2019 - 2020 ABB. All rights reserved.
2 Installation and commissioning
2.4.5 Orienting and securing the robot
Note
(A)
(A)
(B)
B-B
xx1500000250
A Cylindrical guide pin (2 pcs)
B M5 x 40. Tightening torque 6
Nm. (x2)
See
Lifting the robot with roundslings
on page
61.
Make sure the robot base is correctly
fitted onto the guide sleeves!
Specified in
Attachment screws on
page
66.
Note
Lightly lubricate screws before as-
sembly.
Continued
800
B
B
67