6
7
8
9
Product manual - IRB 6790
3HAC063331-001 Revision: B
Action
Inspect the oil level at the vent hole (level
plug).
Remove the oil dispenser.
Apply Mercasol on the nipple.
Refit the protective cap on the nipple.
Refit the level plug.
DANGER
Make sure all safety requirements are met
when performing the first test run.
© Copyright 2019 - 2020 ABB. All rights reserved.
3 Maintenance
3.5.3 Changing oil, axis-2 gearbox
Note
xx1200000952
Required oil level is: 0-15 mm below the oil
plug hole.
More information is found in
oil level in axis-2 gearbox on page
Tightening torque: 24 Nm
Continued
Inspecting the
104.
141