5 Calibration
5.3 Updating revolution counters
Continued
5
6
7
8
622
Action
Tap Update Revolution Counters....
A dialog box is displayed, warning that updating the revolution counters may change
programmed robot positions:
•
Tap Yes to update the revolution counters.
•
Tap No to cancel updating the revolution counters.
Tapping Yes displays the axis selection window.
Select the axis to have its revolution counter updated by:
•
Ticking in the box to the left
•
Tapping Select all to update all axes.
Then tap Update.
A dialog box is displayed, warning that the updating operation cannot be undone:
•
Tap Update to proceed with updating the revolution counters.
•
Tap Cancel to cancel updating the revolution counters.
Tapping Update updates the selected revolution counters and removes the tick from
the list of axes.
CAUTION
If a revolution counter is incorrectly updated, it will cause incorrect manipulator posi-
tioning, which in turn may cause damage or injury!
Check the synchronization position very carefully after each update. See
the synchronization position on page
© Copyright 2019 - 2020 ABB. All rights reserved.
637.
Product manual - IRB 6790
3HAC063331-001 Revision: B
Checking