ABB Robotics IRB 6790 Product Manual page 110

Table of Contents

Advertisement

3 Maintenance
3.3.5 Inspecting the oil level in axis-5 gearbox
Continued
3
4
5
6
7
8
9
110
Action
Make sure that the oil temperature is +25°C
± 10°C.
WARNING
Handling gearbox oil involves several
safety risks, see
Gearbox lubricants (oil or
grease) on page
31.
Open the oil plug.
Check the oil level.
Required oil level is: 0 - 10 mm below the
oil plug hole.
Add or drain oil, if required.
Refit the oil plug.
DANGER
Make sure all safety requirements are met
when performing the first test run.
© Copyright 2019 - 2020 ABB. All rights reserved.
Note
xx1200000959
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes.
Further information about how to drain or
fill with oil is found in section
axis-5 gearbox on page
150.
Tightening torque: 24 Nm.
Product manual - IRB 6790
3HAC063331-001 Revision: B
Changing oil,

Hide quick links: