Mitsubishi Electric RD77MS2 User Manual page 441

Melsec iq-r simple motion module
Hide thumbs Also See for RD77MS2:
Table of Contents

Advertisement

[Pr.50] Setting for the movement amount after near-point dog ON
When using the count method 1 or 2, set the movement amount to the home position after the near-point dog signal turns ON.
(The movement amount after near-point dog ON should be equal to or greater than the sum of the "distance covered by the
deceleration from the home position return speed to the creep speed" and "distance of movement in 10 ms at the home
position return speed".)
■Example of setting for "[Pr.50] Setting for the movement amount after near-point dog ON"
Assuming that the "[Pr.8] Speed limit value" is set to 200 kpulses/s, "[Pr.46] Home position return speed" to 10 kpulses/s,
"[Pr.47] Creep speed" to 1 kpulses/s, and deceleration time to 300 ms, the minimum value of "[Pr.50] Setting for the
movement amount after near-point dog ON" is calculated as follows:
[Home position return operation]
[Pr.8] Speed limit value: Vp = 200 kpulses/s
[Pr.46] Home position return speed:
Vz = 10 kpulses/s
Actual deceleration time: t = Tb ×
[Pr.1] setting value
0: mm
1: inch
2: degree
3: pulse
[Pr.51] Home position return acceleration time selection
Set which of "acceleration time 0 to 3" to use for the acceleration time during home position return.
0: Use the value set in "[Pr.9] Acceleration time 0".
1: Use the value set in "[Pr.25] Acceleration time 1".
2: Use the value set in "[Pr.26] Acceleration time 2".
3: Use the value set in "[Pr.27] Acceleration time 3".
[Pr.52] Home position return deceleration time selection
Set which of "deceleration time 0 to 3" to use for the deceleration time during home position return.
0: Use the value set in "[Pr.10] Deceleration time 0".
1: Use the value set in "[Pr.28] Deceleration time 1".
2: Use the value set in "[Pr.29] Deceleration time 2".
3: Use the value set in "[Pr.30] Deceleration time 3".
[Deceleration distance]
[Pr.47] Creep speed:
Vc = 1 kpulses/s
t
Vz
Deceleration time:
Vp
Tb = 300 ms
Value set with the engineering tool (unit)
0 to 214748364.7 (m)
0 to 21474.83647 (inch)
0 to 21474.83647 (degree)
0 to 2147483647 (pulse)
1
Vz
×
× t
+ 0.01 × Vz
=
2
1000
Movement amount for 10 ms
at home position return speed.
Vz
Tb × Vz
×
+ 0.01 × Vz
=
2000
Vp
3
10 × 10
300 × 10 × 10
×
=
3
2000
200 × 10
= 75 + 100
= 175
*: "[Pr.50] Setting for the movement amount
after near-point dog ON" should be equal to
or larger than 175.
Value set with a program (unit)
0 to 2147483647 (  10
0 to 2147483647 (  10
0 to 2147483647 (  10
0 to 2147483647 (pulse)
12 DATA USED FOR POSITIONING CONTROL
3
3
+ 0.01 × 10 × 10
-1
m)
-5
inch)
-5
degree)
439
12.3 Basic Setting
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd77ms16Rd77ms4Rd77ms8

Table of Contents