Designating the positioning address
The following shows the two methods for commanding the position in control using positioning data.
Absolute system
Positioning is carried out to a designated position (absolute address) having the home position as a reference. This address is
regarded as the positioning address. (The start point can be anywhere.)
Address
100
Address 150
Home position
(Reference point)
100
A point
Incremental system
The position where the machine is currently stopped is regarded as the start point, and positioning is carried out for a
designated movement amount in a designated movement direction.
Movement amount
+100
Movement amount -100
Home position
(Reference point)
100
A point
3 MAJOR POSITIONING CONTROL
58
3.1 Outline of Major Positioning Controls
Address
100
Address
150
Address
300
Address 100
Address 150
150
B point
Within the stroke limit range
Movement amount
Movement amount
Movement
+100
amount
-150
150
B point
Within the stroke limit range
• Start point
End point
300
C point
• Start point
-100
End point
250
300
C point