Step Function - Mitsubishi Electric RD77MS2 User Manual

Melsec iq-r simple motion module
Hide thumbs Also See for RD77MS2:
Table of Contents

Advertisement

Step function

The "step function" is used to confirm each operation of the positioning control one by one.
It is used in debugging work for major positioning control, etc.
A positioning operation in which a "step function" is used is called a "step operation".
In step operations, the timing for stopping the control can be set. (This is called the "step mode".) Control stopped by a step
operation can be continued by setting "step continues (to continue the control)" in the "step start information".
Relation between the step function and various controls
The following table shows the relation between the "step function" and various controls.
: Set when required, : Setting not possible
Control type
Home position return
Machine home position return control
control
Fast home position return control
Major positioning control
Position control
1 to 4-axis speed control
Speed-position switching control, Position-speed switching control
Other control
Manual control
JOG operation, Inching operation
Manual pulse generator operation
Expansion control
Speed-torque control
Step mode
In step operations, the timing for stopping the control can be set. This is called the "step mode". (The "step mode" is set in the
control data "[Cd.34] Step mode".)
The following shows the two types of "step mode" functions.
■Deceleration unit step
The operation stops at positioning data requiring automatic deceleration. (A normal operation will be carried out until the
positioning data requiring automatic deceleration is found. Once found, that positioning data will be executed, and the
operation will then automatically decelerate and stop.)
■Data No. unit step
The operation automatically decelerates and stops for each positioning data. (Even in continuous path control, an automatic
deceleration and stop will be forcibly carried out.)
1-axis linear control
2 to 4-axis linear interpolation control
1-axis fixed-feed control
2 to 4-axis fixed-feed control (interpolation)
2-axis circular interpolation control
3-axis helical interpolation control
Current value changing
JUMP instruction, NOP instruction, LOOP to LEND
Step function
Step applicability
Step operation not possible
Step operation possible
Step operation not possible
Step operation possible
Step operation not possible
Step operation not possible
8 CONTROL SUB FUNCTIONS
8.8 Functions Related to Stop
8
273

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd77ms16Rd77ms4Rd77ms8

Table of Contents