Relation between the software stroke limit function and various controls
: Check valid
: Check is not made when the current feed value is not updated (Page 422 [Pr.21] Current feed value during speed
control) at the setting of "current feed value" in "[Pr.14] Software stroke limit selection" during speed control.
: Check not carried out (check invalid).
: Valid only when "0: valid" is set in the "[Pr.15] Software stroke limit valid/invalid setting".
Control type
Home position
Machine home position
return control
return control
Fast home position return control
Major
Position control
positioning
control
1 to 4-axis speed control
Speed-position switching control, Position-speed
switching control
Other control
Manual control
JOG operation, Inching operation
Manual pulse generator operation
Expansion
Speed-torque control
control
*1 The value in "[Md.20] Current feed value" will differ according to the "[Pr.21] Current feed value during speed control" setting.
*2 When the unit is "degree", check is not made during speed control.
*3 When the unit is "degree", check is not carried out.
Precautions during software stroke limit check
• A machine home position return must be executed beforehand for the "software stroke limit function" to function properly.
• During interpolation control, a stroke limit check is carried out for the every current value of both the reference axis and the
interpolation axis. Every axis will not start if an error occurs, even if it only occurs in one axis.
• During circular interpolation control and 3-axis helical interpolation control (reference axis and interpolation axis), the
"[Pr.12] Software stroke limit upper limit value"/"[Pr.13] Software stroke limit lower limit value" may be exceeded. In this
case, a deceleration stop will not be carried out even if the stroke limit is exceeded. Always install an external limit switch if
there is a possibility the stroke limit will be exceeded.
8 CONTROL SUB FUNCTIONS
240
8.4 Functions to Limit the Control
Limit check
Data set method
Other than "Data set
method"
1-axis linear control
2 to 4-axis axis linear
interpolation control
1-axis fixed-feed
control
2 to 4-axis fixed-feed
control (interpolation)
2-axis circular
interpolation control
3-axis helical
interpolation control
*1*2
*1*2
Current value changing
JUMP instruction, NOP
instruction, LOOP to
LEND
*3
*3
Processing at check
The current value will not be changed if the home position
address is outside the software stroke limit range.
Check not carried out.
Checks 1) and 2) in Page 239 Software stroke limit
check details are carried out.
For speed control: The axis decelerates to a stop when it
exceeds the software stroke limit range.
For position control: The axis comes to an immediate
stop when it exceeds the software stroke limit range.
The current value will not be changed if the new current
value is outside the software stroke limit range.
Check not carried out.
Check 1) in Page 239 Software stroke limit check
details is carried out.
The machine will carry out a deceleration stop when the
software stroke limit range is exceeded. If the address is
outside the software stroke limit range, the operation can
only be started toward the moveable range.
Check 1) in Page 239 Software stroke limit check
details is carried out.
The mode switches to the position control mode when the
software stroke limit range is exceeded, and the
operation immediately stops.