Mitsubishi Electric RD77MS2 User Manual page 89

Melsec iq-r simple motion module
Hide thumbs Also See for RD77MS2:
Table of Contents

Advertisement

■Setting positioning data
When using 2-axis circular interpolation control with sub point designation (ABS circular sub), set the following positioning
data.
: Always set, : Set as required, : Setting restricted, : Setting not required
Setting item
[Da.1]
Operation pattern
[Da.2]
Control method
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time/JUMP destination positioning data No.
[Da.10]
M code/Condition data No./Number of LOOP to LEND repetitions/
Number of pitches
[Da.20]
Axis to be interpolated No.1
[Da.21]
Axis to be interpolated No.2
[Da.22]
Axis to be interpolated No.3
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed designation method
*1 Refer to the following for information on the setting details.
Page 445 Positioning Data
Set a value in "[Da.8] Command speed" so that the speed of each axis does not exceed the "[Pr.8] Speed limit
value". (The speed limit does not function for the speed calculated by the Simple Motion module during
interpolation control.)
Setting required/not required
for the reference axis
(Set ABS circular sub.)
3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
Setting required/not required
for the interpolation axis
3
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd77ms16Rd77ms4Rd77ms8

Table of Contents