Mitsubishi Electric RD77MS2 User Manual page 311

Melsec iq-r simple motion module
Hide thumbs Also See for RD77MS2:
Table of Contents

Advertisement

Pin No.
DI No.
1A1
DI1
1A2
DI2
1A3
DI3
1A4
DI4
1A5
DI5
1B1
DI6
1B2
DI7
1B3
DI8
1B4
DI9
1B5
DI10
Set the input terminal and buffer memory number to be used for each setting value of the "external signal selection" such as
"[Pr.116] FLS signal selection", "[Pr.117] RLS signal selection", "[Pr.118] DOG signal selection" and "[Pr.119] STOP signal
selection".
■When "0: Simple Motion module" is set
The pin number to be used is set as the setting details (input terminal) of "[Pr.116] FLS signal selection", "[Pr.117] RLS signal
selection", "[Pr.118] DOG signal selection", and "[Pr.119] STOP signal selection".
■When "1: Servo amplifier" is set
The following table shows the pin number of the external input signal of the servo amplifier to be used.
(Note): When setting at MR-JE-B use, any errors or warnings do not occur. However, the external input signal (upper/lower
limit signal, near-point dog signal) cannot be operated.
*1
Pin No. of servo amplifier
CN3-19(DI3)
CN3-12(DI2)
CN3-2(DI1)
*1 This servo amplifier means about MR-J4_B/MR-JE-_B. Refer to the "Servo Amplifier Instruction Manual" for details on the pin numbers
of MR-J4W_-_B.
*2 The stop signal cannot be input from the external input signal of the servo amplifier.
■When "2: Buffer memory" is set
Uses the control data shown below to operate the external input signals (upper/lower stroke limit signal, near-point dog signal,
and stop signal).
Setting item
[Cd.44]
External input signal operation
device (Axis 1 to 16)
Refer to the following for the setting details.
Page 504 Control Data
Input logic setting method for external input signals
The signal logic can be switched according to the external input signals (upper/lower stroke limit signal (FLS/RLS), near-point
dog signal (DOG), stop signal (STOP), and external command signal/switching signal (DI)) of the servo amplifier or external
device connected with the Simple Motion module.
For the system that does not use the upper/lower limit signal with b-contact, this function enables the control without wiring by
setting "Positive logic" to the parameter logic setting.
When using the upper/lower limit signal, be sure to use in the negative logic (b-contact).
For the interface of the logic selection, the setting area varies depending on the input type and signal type of the external
signal.
Definition of FLS/
RLS/DOG/STOP
The signal set with the
input terminal setting in
"[Pr.116] FLS signal
selection" to "[Pr.119]
STOP signal selection".
Signal name
DOG
RLS
FLS
Setting value
Setting details
Set the status of the upper/lower limit signal, the
near-point dog signal and the stop signal.
Pin No.
DI No.
2A1
DI11
2A2
DI12
2A3
DI13
2A4
DI14
2A5
DI15
2B1
DI16
2B2
DI17
2B3
DI18
2B4
DI19
2B5
DI20
9.4 External Input Signal Select Function
Definition of FLS/
RLS/DOG/STOP
The signal set with the
input terminal setting in
"[Pr.116] FLS signal
selection" to "[Pr.119]
STOP signal selection".
Buffer memory address
5928 to 5931
9 COMMON FUNCTIONS
309