[Md.60] Start (ms)
The starting time (ms) is stored.
000 (ms) to 999 (ms)
Refresh cycle: At start
■Reading the monitor value
• Monitoring is carried out with a hexadecimal display.
Buffer memory (stored with BCD code)
0
1
0
0
b15
b12
b8
b4
0
0 0 0 0 0 0 1 0 0 0 0 0 0 0 0
0
0 to 9
0 to 9
0 to 9
*1 If a start signal is issued against an operating axis, a record relating to this event may be output before a record relating to an earlier
start signal is output.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 390 Monitor data
[Md.7] Error judgment
This area stores the following results of the error judgment performed upon starting:
• Warning flag
BUSY start
Control mode switching during BUSY
Control mode switching during zero speed OFF
Outside control mode range
Control mode switching
• Error flag
• Error code
Refresh cycle: At start
■Reading the monitor value
• Monitoring is carried out with a hexadecimal display.
A
B
b15
b12
Buffer
memory
a
B
Error flag
Stored contents
Error flag OFF
Error flag ON
Warning flag
Stored contents
Error flag OFF
Error flag ON
*1 If a start signal is issued against an operating axis, a record relating to this event may be output before a record relating to an earlier
start signal is output.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
Page 390 Monitor data
12 DATA USED FOR POSITIONING CONTROL
472
12.7 Monitor Data
Monitor value
b0
0
1
0
000 to 999 (ms)
C
D
b8
b4
b0
C
D
Error code
Convert the hexadecimal value "a, B, C, D" into a decimal
Stored value
value and match it with Section 12.5 List of error codes.
0
1
Stored value
0
1
0
Monitor value
A
B
C
D