Operations when stroke limit error occurs
When the hardware stroke limit error or the software stroke limit error is detected
decelerate to a stop. However, in case of "[Md.26] Axis operation status", "Manual pulse generator operation" will continue
After stopping, manual pulse generator input pulses to the outside direction of the limit range are not accepted, but operation
can be executed within the range.
*1 Only when the current feed value or the machine feed value overflows or underflows during deceleration, the manual pulse generator
operation will terminate as "error occurring". To carry out manual pulse generator operation again, "[Cd.21] Manual pulse generator
enable flag" must be turned OFF once and turn ON.
V
Manual pulse generator operation possible
Upper/lower limit signal
Operation timing and processing time
The following drawing shows details of the manual pulse generator operation timing and processing time.
■RD77MS4 operation example
[Cd. 21] Manual pulse generator
enable flag
Manual pulse generator
input pulses
BUSY signal [X10,X11,X12,X13]
Start complete signal
([Md.31] Status: b14)
[Md.26] Axis operation status
Standby (0)
Positioning operation
Normal timing time (Unit: [ms])
*1
Operation cycle
t1
0.444
0.430 to 0.438
0.888
0.865 to 0.874
1.777
1.735 to 1.748
3.555
3.512 to 3.534
*1 Delays may occur in the t1 timing time due to the operation status of other axes.
Manual pulse generator operation
Manual pulse generator operation not possible
ON
OFF
0
1
t1
The start complete signal does not turn ON in manual pulse generator operation.
Manual pulse generator operation (4)
t2
t2
10.065 to 21.810
10.065 to 21.810
10.065 to 21.810
10.065 to 21.810
*1
during operation, the operation will
0
t3
t4
Standby (0)
t3
14.530 to 23.095
14.530 to 23.095
14.530 to 23.095
14.530 to 23.095
5.4 Manual Pulse Generator Operation
*1
.
t4
7.266 to 15.646
7.266 to 15.646
7.266 to 15.646
7.266 to 15.646
5 MANUAL CONTROL
185