Mitsubishi Electric RD77MS2 User Manual page 132

Melsec iq-r simple motion module
Hide thumbs Also See for RD77MS2:
Table of Contents

Advertisement

Position-speed switching signal setting
• The following table shows the items that must be set to use the external command signals [DI] as position-speed switching
signals.
n: Axis No. - 1
Setting item
[Pr.42]
External command function
selection
[Cd.8]
External command valid
[Cd.45]
Speed-position switching device
selection
*1 Set the external command signal [DI] in "[Pr.95] External command signal selection". Refer to the followings for information on the
setting details.
Page 407 Basic Setting, Page 504 Control Data
• The following table shows the items that must be set to use the near-point dog signal (DOG) as position-speed switching
signals.
n: Axis No. - 1
Setting item
[Cd.45]
Speed-position switching device
selection
*2 The setting is not required for "[Pr.42] External command function selection" and "[Cd.8] External command valid". Refer to the following
for information on the setting details.
Page 504 Control Data
• The following table shows the items that must be set to use "[Cd.46] Speed-position switching command" as position-speed
switching signals.
n: Axis No. - 1
Setting item
[Cd.45]
Speed-position switching device
selection
*3 The setting is not required for "[Pr.42] External command function selection" and "[Cd.8] External command valid". Refer to the following
for information on the setting details.
Page 504 Control Data
3 MAJOR POSITIONING CONTROL
130
3.2 Setting the Positioning Data
Setting value
Setting details
2
2: Speed-position, position-speed switching request.
1
1: Validates an external command.
0
0: Use the external command signal for switching from
position control to speed control.
Setting value
Setting details
1
1: Use the near-point dog signal for switching from
position control to speed control.
Setting value
Setting details
2
2: Use the "[Cd.46] Speed-position switching command"
for switching from position control to speed control.
Buffer memory address
62+150n
4305+100n
4366+100n
Buffer memory address
4366+100n
Buffer memory address
4366+100n

Advertisement