Mitsubishi Electric RD77MS2 User Manual page 67

Melsec iq-r simple motion module
Hide thumbs Also See for RD77MS2:
Table of Contents

Advertisement

Setting the positioning data
When carrying out interpolation control, the same positioning data Nos. are set for the "reference axis" and the "interpolation
axis". The following table shows the "positioning data" setting items for the reference axis and interpolation axis.
: Setting always required, : Set according to requirements (Set to "" when not used.), : Setting restrictions exist
: Setting not required (The setting value is invalid. Use the initial value or a value within the setting range.)
Setting item
Same
[Da.1]
Operation pattern
positioning
[Da.2]
Control method
data Nos
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time/JUMP destination positioning
data No.
[Da.10]
M code/Condition data No./Number of
LOOP to LEND repetitions/Number of
pitches
[Da.20]
Axis to be interpolated No.1
[Da.21]
Axis to be interpolated No.2
[Da.22]
Axis to be interpolated No.3
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed designation method
*1 The axis No. is set to axis to be interpolated No.1 for 2-axis linear interpolation, to axis to be interpolated No.1 and No.2 for 3-axis linear
interpolation, and to axis to be interpolated No.1 to No.3 for 4-axis linear interpolation.
If the self-axis is set, the error "Illegal interpolation description command" (error code: 1A22H) will occur. The axes that are not used are
not required.
*2 Refer to the following for information on the setting details.
Page 445 Positioning Data
Starting the interpolation control
The positioning data Nos. of the reference axis (axis in which interpolation control was set in "[Da.2] Control method") are
started when starting the interpolation control. (Starting of the interpolation axis is not required.)
The following errors or warnings will occur and the positioning will not start if both reference axis and the interpolation axis are
started.
• Reference axis: Interpolation while interpolation axis BUSY (error code: 1998H)
• Interpolation axis: Control method setting error (error code: 199CH), start during operation (warning code: 0900H).
Reference axis setting item
Linear 2, 3, 4
Fixed-feed 2, 3, 4
Circular sub, Circular right, Circular left
Helical sub, Helical right, Helical left
Forward run speed 2, 3, 4
Reverse run speed 2, 3, 4
(Forward run speed 2, 3, and 4. Reverse
run speed 2, 3, and 4 not required.)
(Only during circular sub, circular right,
circular left, helical sub, helical right, and
helical left.)
*1
*1
*1
3.1 Outline of Major Positioning Controls
Interpolation axis setting item
(Forward run speed 2, 3, and 4. Reverse
run speed 2, 3, and 4 not required.)
(Only during circular sub, circular right,
circular left, helical sub, helical right, and
helical left.)
(Only during forward run speed 2, 3, 4 and
reverse run speed 2, 3, 4).
Set the number of pitch for the linear
interpolation axis only during helical sub,
helical right, and helical left.
3 MAJOR POSITIONING CONTROL
3
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd77ms16Rd77ms4Rd77ms8

Table of Contents