■Precautions on parameter setting
• The logic switching parameters are validated when the PLC READY signal [Y0] is turned OFF to ON. (The logic is negative
right after power-on.)
• If the logic of each signal is set erroneously, the operation may not be carried out correctly. Before setting, check the
specifications of the equipment to be used.
Input filter setting method for external input signals
The input filter is used to suppress chattering when the external input signal is chattering by noise, etc.
The setting area of the input filter varies by the input type of "[Pr.116] FLS signal selection" to "[Pr.119] STOP signal selection".
Input type of "[Pr.116] FLS signal selection" to "[Pr.119] STOP
signal selection"
0: Simple Motion module
1: Servo amplifier
2: Buffer memory
■External input signals from the external device connected with the Simple Motion module
(upper/lower stroke limit signal (FLS/RLS), near-point dog signal (DOG), stop signal (STOP),
and external command signal/switching signal (DI))
Use the following parameter to set the input filter of the external input signals from the external device connected with the
Simple Motion module (upper/lower stroke limit signal (FLS/RLS), near-point dog signal (DOG), stop signal (STOP), and
external command signal/switching signal (DI)).
Setting item
[Pr.153]
External input signal
digital filter setting
Precautions
• "[Pr.153] External input signal digital filter setting" is not a parameter for each axis.
• "[Pr.153] External input signal digital filter setting" becomes valid when the power supply is turned ON, the CPU module is
reset, or the PLC READY signal [Y0] is turned ON.
• When lengthening the filter setting time, the signal detection timing will be slow.
• When "[Pr.153] External input signal digital filter setting" is set with a value other than "0 to 6", note that the module may
cause a failure.
Initial value
Setting details
6666H
Filter setting 1
Filter setting 2
Filter setting 3
Filter setting 4
Filter setting 5
Setting area
[Pr.153] External input signal digital filter setting
Input filter setting (PD11)
(Servo parameter)
No setting (No input filter when the buffer memory is set.)
b15
b12
b8
b4
SIN4
SIN 3
SIN2
SIN1
b15
b12
b8
b4
SIN8
SIM7
SIM6
SIM5
b15
b12
b8
b4
SIN12
SIN11
SIN10
SIN9
b15
b12
b8
b4
SIN16
SIN15
SIN14
SIN13
b15
b12
b8
b4
SIN20
SIN19
SIN18
SIN17
9.4 External Input Signal Select Function
0H: 3.2 ms
b0
1H: 2.4 ms
2H: 1.6 ms
3H: 1.2 ms
4H: 0.8 ms
5H: 0.4 ms
b0
6H: 0.2 ms
b0
b0
b0