4.4

Setting the Condition Data

Relation between various controls and the condition data

"Condition data" is set in the following cases.
• When setting conditions during execution of JUMP instruction (major positioning control)
• When setting conditions during execution of "high-level positioning control"
The "condition data" to be set includes the setting items from [Da.15] to [Da.19] and [Da.23] to [Da.26], but the setting
requirements and details differ according to the control method and setting conditions.
The following shows the "condition data" "[Da.15] Condition target" corresponding to the different types of control.
(The "condition data" settings in this chapter are assumed to be carried out using the engineering tool.)
: One of the setting items must be set.
: Setting not possible
[Da.15] Setting item High-level positioning control
*1
01: Device X
*1
02: Device Y
03: Buffer memory
(1 word)
04: Buffer memory
(2 words)
05: Positioning data No.
*1 Refer to devices X/Y which belongs to Simple Motion module.
It is recommended that the "condition data" be set whenever possible with the engineering tool. Execution by
a program uses many programs and devices. The execution becomes complicated, and the scan times will
increase.
4 HIGH-LEVEL POSITIONING CONTROL
156
4.4 Setting the Condition Data
Block start
Wait start
Simultaneous start
Repeated start
(For condition)
Major positioning
control
JUMP instruction

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd77ms16Rd77ms4Rd77ms8

Table of Contents