Multifrequency-Signaling-Related Parameters
Outgoing Forward Signal Absent Timer (sec)
This field appears only when the content of
Valid
entries
11 to 255
Outgoing Forward Signal Present Timer (sec)
This field appears only when the value of
Valid
entries
1 to 255
Outgoing Start Timer (sec)
Appears when the Incoming Call Type field is mfe.
Valid
entries
1 to 255
1082
Outgoing Call Type
Usage
Enter the maximum number of seconds to elapse between forward
signals on outgoing calls. The timer starts (and restarts) when a
forward tone is taken off the link and it stops when the next forward
tone is applied to the link.
Outgoing Call Type
Usage
Enter the maximum number of seconds to elapse between signals on a
call. This timer runs when MFC tones are being sent or received on an
outgoing call. The timer starts (and restarts) when Communication
Manager begins sending a forward signal and stops when
Communication Manager receives the backward signal.
Usage
Enter the number of seconds to time from seizure until the beginning of
the first Group A signal from the receiving end, and from the end of the
check frequency until the beginning receipt of the first digit following
the Group II signal.
Administrator's Guide for Avaya Communication Manager
is group-ii-mfc.
is group-ii-mfc.