Received Digital Metering Pulse Minimum
(ms)
This field appears only when the
field is co or pbx, and the
Interconnect
periodic pulse metering (PPM) as defined in
Country Protocol code),
Valid entries
20 to 1000 ms
in increments of
10ms.
Received Digital Metering Pulse Value
This field appears when the
field is 21, and the
Protocol
Valid entries
0, 1
Table 16: Incoming digital PPM signaling default (per Country Protocol code) 1 of 2
Code
Country
0
null
1
U.S.
2
Australia
3
Japan
4
Italy
5
Netherlands
6
Singapore
7
Mexico
8
Belgium
9
Saudi Arabia
10
UK
11
Spain
12
France
13
Germany
14
Czech Republic
Administrator's Guide for Avaya Communication Manager
November 2003
field is cas (Channel Associated Signaling), the
Signal Mode
Country Protocol
Table 16, Incoming digital PPM signaling default (per
on page 791. The default value depends on the
Usage
Work with your network services provider to determine the
appropriate entry. The entry must be less than the
Metering Pulse Maximum
field is cas (Channel Associated Signaling), the
Signal Mode
field is co or pbx.
Interconnect
Usage
Work with your network services provider to determine the
appropriate entry.
PPM Min (ms)
NA
NA
80
NA
120
90
NA
20
20
NA
NA
20
NA
NA
20
field is administered for a protocol that uses
Country Protocol
Received Digital
field.
PPM Max (ms)
PPM Value
NA
NA
NA
NA
180
0
NA
NA
150
1
160
0
NA
NA
180
1
180
1
NA
NA
NA
NA
220
0
NA
NA
NA
NA
420
1
Screen Reference
DS1 Circuit Pack
field's entry.
Country
1 of 2
791

Advertisement

Table of Contents
loading

Table of Contents