Avaya Communication Manager Administrator's Manual page 846

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Screen Reference
Feature-Related System Parameters
Use Trunk COR for Outgoing Trunk
Disconnect
Use this field to indicate whether the Outgoing Trunk Disconnect Timer is set based on the COR of the
originating station or of the trunk group. If enabled, the timer is based on the COR of the trunk, not the
originating caller's station.
Valid entries
n
y
DISTINCTIVE AUDIBLE ALERTING
Attendant Originated Calls
Valid entries
internal
external
priority
Distinctive Audible Alerting (Internal,
External, Priority)
This is also known as Distinctive Ringing.
Valid entries
1 through 3.
DTMF Tone Feedback Signal to VRU -
Connection, Disconnection
This field appears only if DTMF Feedback Signals for VRU on the Customer-Options System
Parameters screen is y.
Valid entries
0 through 9, *,
#, A, B, C, D
blank
846
Usage
Default. The Outgoing Trunk Disconnect Timer
to be set based on the COR of the originating
station.
Enter y to enable the Outgoing Trunk
Disconnect Timer to be set based on the COR of
the trunk instead of the originating station.
Usage
Indicates which type of ringing (defined above) applies to
attendant-originated calls.
Usage
Enter the number of rings for internal, external and priority calls.
For virtual stations, this applies to the mapped-to physical phone.
Usage
Enter the code to connect or disconnect the VRU. This can be a
single digit, or a combination such as *99 to connect, #99 to
disconnect. The tones must be programmed at the VRU as well.
Blank means that no tone is to be sent to the VRU.
Administrator's Guide for Avaya Communication Manager
November 2003

Advertisement

Table of Contents
loading

Table of Contents