Avaya Communication Manager Administrator's Manual page 737

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Multimedia
Used with the 7500 and World Class BRI Data Modules. Appears only if, on the System-Parameters
Customer-Options screen, the
Valid entries
y/n
Name
Enter the name of the user associated with the data module. The name is optional and can be blank.
Valid entries
Up to 27 alphanumeric characters
Network uses 1's for Broadcast Addresses
Used with Ethernet data modules. See Administration for Network Connectivity for Avaya
Communication Manager for more information.
Node Name
Used with Ethernet (not on S8700 IP-Connect) and Point-to-Point data modules. See Administration for
Network Connectivity for Avaya Communication Manager for more information.
PDATA Port
Used with System Port Data Modules. Enter a seven-digit alphanumeric port location to which the data
module is connected. Used to relate the physical PDATA port to which the mode 3 portion of the system
port is connected. This entry must be assigned to a port on a PDATA Line Board.
Valid entries
01 through 22
01 through 64
A through E
01 through 20
01 through 12
Administrator's Guide for Avaya Communication Manager
November 2003
MM
field is y.
Usage
Enter y to make this data module part of a multimedia complex.
Usage
Usage
First and second characters are the cabinet number
First and second characters are the cabinet number (S8700
IP-Connect)
Third character is the carrier
Fourth and fifth characters are the slot number in the carrier
Sixth and seventh characters are the circuit number
Screen Reference
Data modules
737