Screen Reference
Data modules
ITC
(Information Transfer Capability) Used with 7500, Announcement, data-line, Netcon, Processor/Trunk
(pdm selection), Processor Interface, and System Port Data Modules. Appears only when, on the Trunk
Group screen, the
be used for ISDN calls originated from this endpoint. Does not display for voice-only or BRI stations.
Valid entries
restricted
unrestricted
Link
Used with X.25, Ethernet, Point-to-Point, and Processor Interface (used with DEFINITYCSI and SI only)
data modules. See Administration for Network Connectivity for Avaya Communication Manager for more
information. This field is in different locations on the screen for different data module types.
Valid entries
1-99
Maintenance Extension
Used with Netcon and Processor Interface Data Modules.
Valid entries
Enter the extension number required to
perform maintenance functions on the
standby netcon physical channel in a
duplicated system.
MM Complex Voice Ext
Used with 7500 and World Class BRI Data Modules. Does not appear on S8700 IP-Connect. This field
contains the number of the associated phone in the multimedia complex. This field appears only after you
set the
Multimedia
Complex Data Ext on the Station screen.
Valid entries
Valid values
conform to your
dial plan
736
Comm Type
field is 56k-data or 64k-data. Indicates type of transmission facilities to
Usage
Either restricted or unrestricted transmission facilities are used to
complete the call. A restricted facility is a transmission facility that
enforces 1's density digital transmission (that is, a sequence of 8
digital zeros are converted to a sequence of 7 zeros and a digital 1).
Only unrestricted transmission facilities are used to complete the
call. An unrestricted facility is a transmission facility that does not
enforce 1's density digital transmission (that is, digital information
is sent exactly as is).
Usage
Enter a communication interface link number.
field to y. This field is left blank until you enter the data module extension in MM
Usage
Once you complete the field on the Station screen, these two
extensions are associated as two parts of a one-number complex,
which is the extension of the telephone.
Administrator's Guide for Avaya Communication Manager
Usage
The standby remote loop around tests
fails if this field is not administered.