Renesas H8S/2319 series Hardware Manual page 497

Renesas 16-bit single-chip microcomputer
Table of Contents

Advertisement

Initialization
Start of reception
Read MPIE bit in SCR
Read ORER and FER flags in SSR
FER ∨ ORER = 1?
No
Read RDRF flag in SSR
No
RDRF = 1?
Yes
Read receive data in RDR
No
This station's ID?
Yes
Read ORER and FER flags in SSR
FER ∨ ORER = 1?
No
Read RDRF flag in SSR
RDRF = 1?
Yes
Read receive data in RDR
No
All data received?
Yes
Clear RE bit in SCR to 0
<End>
Figure 12-12 Sample Multiprocessor Serial Reception Flowchart
[1]
SCI initialization:
[1]
The RxD pin is automatically
designated as the receive data
input pin.
[2]
ID reception cycle:
[2]
Set the MPIE bit in SCR to 1.
[3]
SCI status check, ID reception
and comparison:
Yes
Read SSR and check that the
RDRF flag is set to 1, then read
the receive data in RDR and
compare it with this station's ID.
[3]
If the data is not this stationÕs
ID, set the MPIE bit to 1 again,
and clear the RDRF flag to 0.
If the data is this station's ID,
clear the RDRF flag to 0.
[4]
SCI status check and data
reception:
Read SSR and check that the
RDRF flag is set to 1, then read
the data in RDR.
[5]
Receive error handling and break
detection:
If a receive error occurs, read the
ORER and FER flags in SSR to
Yes
identify the error. After
performing the appropriate error
handling, ensure that the ORER
and FER flags are both cleared
to 0.
[4]
Reception cannot be resumed if
either of these flags is set to 1.
No
In the case of a framing error, a
break can be detected by reading
the RxD pin value.
[5]
Error handling
(Continued on
next page)
Rev. 5.00, 12/03, page 467 of 1088

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8s/2318 series

Table of Contents