Table 12-11 Receive Error Conditions
Receive Error
Abbreviation
Overrun error
ORER
Framing error
FER
Parity error
PER
Figure 12-8 shows an example of the operation for reception in asynchronous mode.
Start
1
bit
0
D0
RDRF
FER
Condition
When the next data reception is
completed while the RDRF flag
in SSR is set to 1
When the stop bit is 0
When the received data differs
from the parity (even or odd) set
in SMR
Data
Parity
bit
D1
D7
0/1
RXI interrupt
request
generated
1 frame
Figure 12-8 Example of SCI Receive Operation
(Example with 8-Bit Data, Parity, One Stop Bit)
Stop
Start
bit
bit
1
0
D0
D1
RDR data read and RDRF
flag cleared to 0 in RXI
interrupt handling routine
Rev. 5.00, 12/03, page 461 of 1088
Data Transfer
Receive data is not
transferred from RSR to
RDR
Receive data is transferred
from RSR to RDR
Receive data is transferred
from RSR to RDR
Data
Parity
Stop
bit
bit
Idle state
0
D7
0/1
(mark state)
ERI interrupt request
generated by framing
error
1