• Serial data reception (asynchronous mode)
Figure 12-7 shows a sample flowchart for serial reception.
The following procedure should be used for serial data reception.
Start of reception
Read ORER, PER, and
FER flags in SSR
PER ∨ FER ∨ ORER = 1?
Read RDRF flag in SSR
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
No
All data received?
Clear RE bit in SCR to 0
Rev. 5.00, 12/03, page 458 of 1088
Initialization
No
Error handling
(Continued on next page)
RDRF = 1?
Yes
Yes
<End>
Figure 12-7 Sample Serial Reception Flowchart
[1]
SCI initialization:
[1]
The RxD pin is automatically
designated as the receive data
input pin.
[2] [3]
Receive error handling and
break detection:
If a receive error occurs, read the
[2]
ORER, PER, and FER flags in
SSR to identify the error. After
performing the appropriate error
Yes
processing, ensure that the
ORER, PER, and FER flags are
[3]
all cleared to 0. Reception cannot
be resumed if any of these flags
are set to 1. In the case of a
framing error, a break can be
detected by reading the value of
[4]
the input port corresponding to
the RxD pin.
[4]
SCI status check and receive
data read :
Read SSR and check that RDRF
= 1, then read the receive data in
RDR and clear the RDRF flag to
0. Transition of the RDRF flag
from 0 to 1 can also be identified
by an RXI interrupt.
[5]
Serial reception continuation
[5]
procedure:
To continue serial reception,
before the stop bit for the current
frame is received, read the
RDRF flag, read RDR, and clear
the RDRF flag to 0. The RDRF
flag is cleared automatically
when the DTC is activated by an
RXI interrupt and the RDR value
is read.