Test Remote Access Interface

Test the communication link between the media server and the remote access interface and
verify the alarm notification process. Make a remote test from the remote interface to the Avaya
S8700 Media Server and a local test from the Avaya S8700 Media Server to the remote
interface.
In some countries, this remote access interface is not allowed. Contact your Avaya
representative.

Test Terminating Trunk Transmission

The Terminating Trunk Transmission Test provides for extension number access to 3 tone
sequences that can be used for trunk transmission testing from the distant end of the trunks.
Type change system-parameters maintenance and press
1
2
Under TERMINATING TRUNK TRANSMISSION TEST ( Extension ), type in 3
extension numbers in the 3 fields provided:
Test Type 100:_______Test Type 102:_______Test Type 105:_______
Test Type
Test Features
Test type 100
5.5 seconds of 1004 Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute
Test Type
9 seconds of 1004 Hz tone at 0 dB
102
1 second of silence
Cycle is repeated until disconnect, which is forced after 24
hours
Test Type
9 seconds of 1004 Hz tone at -16 dB
105
1 second of silence
9 seconds of 404 Hz tone at -16 dB
1 second of silence
9 seconds of 2804 Hz tone at -16 dB
30 seconds of silence
0.5 seconds of test progress tone (2225 Hz)
About 5 seconds of silence
Forced disconnect