Clear Ais-V On Ds3Xm-6 Unused Vt Circuits; Circuit Creation Error With Vt1.5 Circuit - Cisco ONS 15454 Troubleshooting Manual

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

1.9.3 Circuit Creation Error with VT1.5 Circuit

Table 1-28 Calculate and Design IP Subnets
Possible Problem
The port on the
reporting node is
in-service but a node
upstream on the circuit
does not have an OC-N
port in service.

Clear AIS-V on DS3XM-6 Unused VT Circuits

Note
This procedure does not apply to Software R4.6 DWDM cards or ML-Series cards.
Step 1
Determine the affected port.
Record the node ID, slot number, port number, or VT number.
Step 2
Create a unidirectional VT circuit from the affected port back to itself, such as Source node/
Step 3
Slot 2/Port 2/VT 13 cross connected to Source node/Slot 2/Port 2/VT 13.
Uncheck the bidirectional check box in the circuit creation window.
Step 4
Give the unidirectional VT circuit an easily recognizable name, such as "delete me."
Step 5
Display the DS3XM-6 card in CTC card view. Click the Maintenance > DS1 tabs.
Step 6
Locate the VT that is reporting the alarm (for example, DS3 #2, DS1 #13).
Step 7
From the Loopback Type list, choose Facility (Line) and click Apply.
Step 8
Click Circuits.
Step 9
Find the one-way circuit you created in
Step 10
Step 11
Click Yes in the Delete Confirmation dialog box.
Step 12
Display the DS3XM-6 card in CTC card view. Click Maintenance > DS1.
Step 13
Locate the VT in Facility (line) Loopback.
Step 14
From the Loopback Type list, choose None and then click Apply.
Step 15
Click the Alarms tab and verify that the AIS-V alarms have cleared.
Step 16
Repeat this procedure for all the AIS-V alarms on the DS3XM-6 cards.
1.9.3 Circuit Creation Error with VT1.5 Circuit
Symptom
create connection object at node_name" message when trying to create a VT1.5 circuit in CTC.
Table 1-29
Cisco ONS 15454 Troubleshooting Guide, R4.6
1-90
Solution
An AIS-V indicates that an upstream failure occurred at the virtual tributary
(VT) layer. AIS-V alarms also occur on DS3XM-6 VT circuits that are not
carrying traffic and on stranded bandwidth.
Complete the
on page
1-90.
You receive an "Error while finishing circuit creation. Unable to provision circuit. Unable to
describes the possible problem and the solution.
"Clear AIS-V on DS3XM-6 Unused VT Circuits" procedure
Step
3. Select the circuit and click Delete.
Chapter 1
General Troubleshooting
November 2004