MAIN POSITIONING CONTROL

9.1.3 Designating the positioning address

The following shows the two methods for commanding the position in control using
positioning data.
Absolute system
Positioning is carried out to a designated position (absolute address) having the
zero point as a reference. This address is regarded as the positioning address.
(The start point can be anywhere.)
Address
Address
100
Address 150
100
A point
Within the stroke limit range
Fig. 9.6 Absolute system positioning
Increment system
The position where the machine is currently stopped is regarded as the start point,
and positioning is carried out for a designated movement amount in a designated
movement direction.
Movement amount
+100
Movement amount +100
Movement
amount -150
Movement amount-100
100
A point
Within the stroke limit range
Fig. 9.7 Increment system positioning
Address
100
150
Address
300
Address 100
Address 150
150
B point
Movement amount
-100
Movement amount
+100
Movement amount+50
150
B point
9 - 14
MELSEC-A
·
Start point
End point
300
C point
·
Start point
End point
300
C point