ALARM-PT (ALARM PORT)

ALARM-PT (ALARM PORT)
MO Name (in
Alarm Log)
ALARM-PT
ALARM-PT
1
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the
carrier designation (for example, A, B, C, D, or E); SS is the address of the slot in
the carrier where the circuit pack is located (for example, 01, 02,...,etc.); and pp
is the 2-digit port number (for example, 01).
The Alarm Port Maintenance Object provides on-board maintenance for an
analog line port that is administered as an external device alarm port. Tests are
provided to verify the analog line port's ability to detect an external device alarm.
The External Device Alarm (EXT-DEV) Maintenance Object is used for the
off-board external device alarm.
555-233-123
Alarm
Initial Command to
Level
Run
MIN
test port PCSSpp l
WRN
test port PCSSpp sh
1
Full Name of MO
Alarm-Port
Alarm-Port
Issue 4 May 2002
10-43