Maintenance-Object Repair Procedures

ALARM-PT (ALARM PORT)

MO's Name (in
Alarm Log)
ALARM-PT
ALARM-PT
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02,...).
The Alarm port MO provides on-board maintenance for an analog line port that is
administered as an external device alarm port. Tests are provided to verify the
analog line ports ability to detect an external device alarm. The external device
alarm (EXT-DEV) MO is used for the off-board external device alarm.
Error Log Entries and Test to Clear Values
Table 8-16. 8-Port Analog Line Error Log Entries
Error
Aux
Type
Data
1
0
0
15 (a)
Any
18
0
130 (b)
769
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate errors.
b. Indicates that the circuit pack has been removed or has been insane for
more than 11 minutes. To clear the error, reseat or replace the circuit pack.
8-42
Issue 1 May 2002
Alarm
Level
Initial Command to Run
MINOR
test port UUCSSpp l
WARNING
test port UUCSSpp sh
Alarm
Associated Test
Level
Any
Any
Audits and
Updates test
(#36)
busyout
WARNING
station
extension
None
WARNING
Battery Feed
MINIOR
test (#35)
1
Full Name of MO
Alarm-Port
Alarm-Port
On/Off
Board
Test to Clear Value
Any
test port UUCSSpp sh r 1
OFF
release station extension
ON
test port UUCSSpp sh
ON
test port UUCSSpp sh r 2
555-233-143