Set Neon Voltage (Ring Ping)
Set Neon Voltage (Ring Ping)
NOTE:
If the ringing option is set to 50 Hz, neon voltage is not available. If 25 Hz is
selected, the maximum voltage is 120 volts.
If LED message lamps are used, or there are no neon message waiting lamps, or
if the 50-Hz ring option is selected, use this step.
Figure 4. Setting the Neon Voltage
1. Call a telephone with a neon message indicator and leave a message.
2. Check for "ring ping" (single ring pulse) each time the lamp flashes
(approximately every 3 seconds).
3. Adjust the neon voltage control clockwise in small increments until the ring
ping stops. See
the adjustment is finished.
4. Enter logoff and press
unauthorized changes to data.
5. Set the left and right doors onto the hinge pins and close the doors. The
doors must be closed to prevent EMI emissions. Tighten the door screws.
6. Set the cover panel onto the right panel and secure.
555-233-119
Figure
4. Be sure that the message lamp still lights when
to logoff the system and to prevent
Enter
didmt1 KLC 053097
Issue 5 October 2002
51