Serial Port Configuration

Use MANAGEMENT/Serial Port to navigate to this page.
Use this page to modify configurable serial session properties.
Table -
Serial Session Properties
Parameter
Serial Port Login
Timeout
Baud Rate (bps)
Character Size
Flow Control
Stop Bits
Parity
Command Buttons
Apply: Data is sent to the Alcatel OmniAccess Switch or Appliance and made to take effect, but
not preserved across a power cycle; these parameters are stored temporarily in volatile RAM.
Help: Request that the help page be displayed in a new browser window.

Local Management Users

Use MANAGEMENT/Local Management Users to navigate to this page.
This page lists current management user logins on the Alcatel OmniAccess Switch or Appliance and the
users' access privileges.
You may remove a user account by selecting Remove. Removing the default admin user prohibits both
Web and CLI access to the Alcatel OmniAccess Switch or Appliance, so you must create a user provide
with administrative (read/write) privileges BEFORE you remove the default user.
Command Buttons
New: Select to add a new management user
Help: Request that the help page be displayed in a new browser window.
Local Management Users > New
Use MANAGEMENT/Local Management Users then New... to navigate to this page.
11/5/04
90-100831-300 Rev 2Alcatel OmniAccess Wireless Access Point Quick Installation Guide 118
Serial Port Configuration
Description
Specifies the time, in minutes, of
inactivity on a Serial port connection,
after which the Alcatel OmniAccess
Switch or Appliance closes the
connection.
The default baud rate at which the
serial port tries to connect. This is
selected from a pull-down menu.
The number of bits in a character.
Whether hardware flow-control is
enabled or disabled.
The number of Stop bits per
character.
The parity method used on the Serial
Port.
Local Management Users
Local Management Users > New
Any numeric value between 0 and
160 is allowed.
The default is 5. A value of 0 disables
the timeout.
The available values are 1200, 2400,
4800, 9600, 19200, 38400,57600,
and 115200 baud. The Default is 9600
baud.
8 (read-only).
Disabled (read-only).
1 (read-only).
None (read-only).
(Local Management Users >
Serial Port Configuration
Range
New).